3011686
Current Transformer
Cummins®

AVAILABLE

Cummins®

Ships within 1-3 business days

$129.95 $154.64

This truck part is made by Cummins®. We guarantee that all of our parts are from the OEM (original equipment manufacturer), ensuring a proper fit and quality manufacturing.


DESCRIPTION

The Cummins 3011686 Current Transformer is a specialized component designed for use in the electrical systems of commercial trucks. Its purpose is to facilitate the monitoring and control of electrical current within the truck’s system, ensuring efficient and safe operation. This component is integral to maintaining the electrical integrity and performance of commercial vehicles.

Basic Concepts of Current Transformers

A current transformer is an electrical device used to measure alternating current (AC) in a circuit. It works by stepping down the current to a manageable level for measurement and control purposes. Current transformers are widely used in electrical systems to provide accurate current readings without interrupting the circuit. They play a role in protecting electrical equipment, monitoring system performance, and ensuring safety in high-current applications 1.

Purpose of the Cummins 3011686 Current Transformer

The Cummins 3011686 Current Transformer serves a specific function within the electrical system of a commercial truck. It is designed to monitor and control the electrical current flowing through the system. By providing accurate current measurements, it helps in the efficient management of electrical loads, protection of electrical components from overloads, and ensures the overall reliability of the truck’s electrical system.

Key Features

The Cummins 3011686 Current Transformer is characterized by several key features that enhance its performance. Its design is tailored for durability and accuracy in demanding commercial truck environments. Constructed from high-quality materials, it is built to withstand the rigors of heavy-duty use. Unique attributes such as precise current measurement capabilities and robust construction contribute to its effectiveness in commercial truck applications.

Benefits

Utilizing the Cummins 3011686 Current Transformer offers several advantages. It contributes to improved efficiency of the electrical system by enabling precise current monitoring and control. This leads to better management of electrical loads and reduced risk of component failure due to overloads. Additionally, it enhances safety by providing accurate current readings, which are crucial for the protection of electrical systems in heavy-duty applications. The reliability of the Cummins 3011686 Current Transformer makes it a valuable component for ensuring the consistent performance of commercial trucks.

Installation and Integration

Proper installation and integration of the Cummins 3011686 Current Transformer into a truck’s electrical system are crucial for its effective operation. Guidelines for installation include ensuring the transformer is correctly positioned within the circuit to accurately measure current flow. It is important to follow manufacturer recommendations for installation to avoid potential issues. Precautions such as ensuring the electrical system is de-energized during installation and using appropriate tools and techniques are necessary to maintain safety and integrity during the installation process.

Troubleshooting and Maintenance

For troubleshooting common issues with the Cummins 3011686 Current Transformer, it is important to first verify the installation and integration were performed correctly. Maintenance tips include regular inspection for signs of wear or damage, ensuring connections are secure, and verifying the accuracy of current readings. Signs of potential failure may include inconsistent current readings, physical damage to the transformer, or indications of overheating. Addressing these issues promptly can help maintain the longevity and optimal performance of the current transformer.

Safety Considerations

When working with the Cummins 3011686 Current Transformer, it is important to adhere to safety practices. This includes ensuring the electrical system is de-energized before beginning any work, using appropriate personal protective equipment, and following all manufacturer guidelines for handling, installation, and maintenance. These safety measures are designed to protect both the technician and the equipment during all phases of interaction with the current transformer.

Cummins Overview

Cummins Inc. is a global power leader that designs, manufactures, and distributes engines, filtration, and power generation products. With a history of innovation and excellence, Cummins has established a strong reputation in the commercial truck industry. The company’s commitment to quality and performance is evident in its wide range of products, including the Cummins 3011686 Current Transformer, which is designed to meet the demanding requirements of commercial truck applications.

Cummins Current Transformer 3011686 Compatibility with Engine Models

The Cummins Current Transformer 3011686 is designed to integrate seamlessly with a variety of engine models, ensuring reliable performance and compatibility. This part is engineered to meet the specific electrical requirements of the following engines:

K Series Engines

  • K19: The 3011686 Current Transformer is compatible with the K19 engine, providing essential electrical monitoring and protection.
  • K38: This transformer fits the K38 engine, ensuring accurate current measurement and safeguarding the engine’s electrical systems.
  • K50: The K50 engine also benefits from the 3011686 Current Transformer, which is tailored to handle the electrical demands of this model.

N Series Engines

  • N14 MECHANICAL: The 3011686 Current Transformer is specifically designed to work with the N14 MECHANICAL engine, ensuring optimal performance and reliability.
  • NH/NT 855: This transformer is also compatible with the NH/NT 855 engine, providing the necessary current transformation and protection.

V Series Engines

  • V28: The Cummins Current Transformer 3011686 is engineered to fit the V28 engine, ensuring it meets the electrical specifications required for this model.

Each of these engines relies on the 3011686 Current Transformer to maintain the integrity of their electrical systems, providing accurate readings and protection against potential electrical faults.

Role of Part 3011686 Current Transformer in Engine Systems

In engine systems, the part 3011686 current transformer is instrumental in ensuring accurate and reliable measurement of electrical current. This component is integral to the operation of the ammeter, which is responsible for displaying the current flowing through a circuit.

When electrical current passes through the primary winding of the current transformer, it induces a proportional current in the secondary winding. This secondary current is significantly lower than the primary current, making it safe and practical for measurement instruments like the ammeter.

The current transformer isolates the ammeter from the high currents present in the primary circuit, thereby protecting the ammeter from potential damage. Additionally, it allows the ammeter to provide precise readings without being subjected to the full load current, enhancing its longevity and accuracy.

In summary, the part 3011686 current transformer plays a significant role in maintaining the integrity and functionality of the ammeter within engine systems, ensuring that current measurements are both accurate and safe.

Conclusion

The Cummins 3011686 Current Transformer is a vital component in the electrical systems of commercial trucks, offering precise current monitoring and control. Its robust design, compatibility with various engine models, and the safety it provides make it an essential part for ensuring the efficient and reliable operation of commercial vehicles. Proper installation, maintenance, and adherence to safety practices are crucial for maximizing the benefits of this Cummins part.


  1. Pedram Asef, Sanjeevikumar Padmanaban, and Andrew Lapthorn, Modern Automotive Electrical Systems (Wiley, 2022).

SPECIFICATIONS

Hazardous Material
Non-Hazardous (NOI, ICE/Auto)
Package Dimensions
8.13 x 7.25 x 2.75 in
Weight
1.51 lb
* This information is provided as is and may be out of date. Please contact us or the manufacturer to verify warranty coverage.
* Variable geometry turbocharger and electronic actuator repairs are not eligible to be claimed as over-the-counter under New or ReCon parts warranty for parts installed after October 1, 2018.
* Diesel Oxidation Catalyst (DOC), Diesel Particulate Filter (DPF), Selective Catalyst Reduction (SCR) catalyst, and Electronic Control Module (ECM) repairs are not eligible to be claimed as over-the-counter under New or ReCon parts warranty for parts installed after January 1, 2020.
* These restrictions are only applicable to New parts and ReCon parts coverages for the components listed above sold to a customer in the US or Canada. All other coverages are excluded. All other regions are excluded.