3011674
Current Transformer
Cummins®

AVAILABLE

Cummins®

Ships within 1-3 business days

$134.95 $160.59

This truck part is made by Cummins®. We guarantee that all of our parts are from the OEM (original equipment manufacturer), ensuring a proper fit and quality manufacturing.


DESCRIPTION

The Cummins 3011674 Current Transformer is a specialized component designed for use in commercial truck operations. Its purpose is to facilitate the monitoring and management of electrical current within the truck’s systems. By providing accurate current measurements, it plays a role in ensuring the efficient and safe operation of the truck’s electrical components 1.

Basic Concepts of Current Transformers

A current transformer is a type of transformer that measures current flow. It works by inducing a proportional current in a secondary winding, which can then be measured using instruments. This allows for the safe and accurate monitoring of high current levels without directly interfacing with the high-voltage primary circuit. Current transformers are commonly used in electrical systems to facilitate metering, protection, and monitoring functions 2.

Purpose of the Cummins 3011674 Current Transformer

The Cummins 3011674 Current Transformer serves a specific role within the electrical system of a commercial truck. It is designed to measure the current flowing through the primary circuit and provide a proportional current in the secondary circuit. This measurement is used for monitoring and controlling the electrical load, ensuring that the truck’s systems operate within safe parameters. It also plays a role in protecting the electrical system from overloads and faults by providing data that can trigger protective measures 3.

Key Features

The Cummins 3011674 Current Transformer is characterized by several key features that enhance its performance. Its design incorporates high-quality materials to ensure durability and accuracy in current measurement. The transformer is engineered to withstand the harsh environments typical of commercial truck operations, including vibrations, temperature fluctuations, and electrical noise. Additionally, it features precise winding ratios and insulation to maintain accuracy and safety in current transformation 4.

Benefits

The Cummins 3011674 Current Transformer offers several benefits to commercial truck operations. By providing accurate current measurements, it contributes to the efficient operation of the truck’s electrical system. This can lead to improved fuel efficiency and reduced maintenance costs. Additionally, the transformer enhances safety by enabling the early detection of electrical faults and overloads, allowing for timely intervention. Its reliable performance ensures consistent operation of the truck’s electrical components, contributing to overall vehicle reliability 5.

Installation and Integration

Proper installation and integration of the Cummins 3011674 Current Transformer within a truck’s electrical system are important for optimal performance. Installation should be conducted by qualified personnel following manufacturer guidelines to ensure accurate current measurement and system compatibility. Considerations include proper alignment with the primary circuit, secure mounting to withstand vibrations, and correct connection of the secondary circuit to monitoring or protective devices 6.

Troubleshooting and Maintenance

Regular maintenance and troubleshooting procedures are important to ensure the longevity and optimal performance of the Cummins 3011674 Current Transformer. Maintenance tips include periodic inspection for signs of wear or damage, ensuring secure connections, and verifying the accuracy of current measurements. Troubleshooting common issues may involve checking for loose connections, inspecting insulation for damage, and verifying the transformer’s alignment with the primary circuit 7.

Safety Considerations

When working with the Cummins 3011674 Current Transformer, it is important to observe several safety practices and precautions. These include ensuring the electrical system is de-energized before installation or maintenance, using appropriate personal protective equipment, and following manufacturer guidelines for handling and installation. Additionally, it is important to be aware of the potential for electrical shock and to take precautions to avoid contact with live circuits 8.

Cummins Overview

Cummins Inc. is a global power leader that designs, manufactures, and distributes a wide range of power solutions, including engines, filtration, and emissions solutions. With a history spanning over a century, Cummins has established a reputation for quality, innovation, and reliability in the commercial truck industry. The company’s commitment to advancing technology and improving efficiency is evident in its product offerings, including the Cummins 3011674 Current Transformer 9.

Cummins Current Transformer 3011674 in NH/NT 855 Engines

The Cummins Current Transformer 3011674 is a critical component in the NH/NT 855 engine series. This part is integral to the engine’s electrical system, ensuring accurate monitoring and regulation of current flow. By converting high current levels into a lower, measurable output, the current transformer provides essential data for the engine’s control systems. This data is vital for maintaining optimal performance and preventing potential damage due to electrical overloads 10.

In the NH/NT 855 engines, the current transformer is typically integrated into the engine’s electrical architecture, working in conjunction with other sensors and control units. Its precise function allows for real-time monitoring of the engine’s electrical load, contributing to the overall efficiency and reliability of the engine. This part is designed to withstand the demanding conditions of engine operation, ensuring long-term durability and consistent performance 11.

Role of Part 3011674 Current Transformer in Engine Systems

In the context of engine systems, the 3011674 Current Transformer is instrumental in ensuring accurate and reliable measurements and control functions. Here’s how it integrates with various components:

Ammeter

The current transformer (CT) is essential for the accurate operation of the ammeter. By stepping down high currents to a manageable level, the CT allows the ammeter to measure current without being exposed to potentially damaging high-current levels. This ensures precise current readings, which are vital for monitoring engine performance and diagnosing issues 12.

Excitation Control Board (ECB)

In conjunction with the excitation control board, the CT provides critical data on current flow. This information is used by the ECB to adjust the excitation levels of the generator, ensuring optimal performance and efficiency. Accurate current measurement helps maintain the correct voltage levels and protects the generator from overexcitation 13.

Paralleling Module

When engines are operated in parallel, the CT plays a significant role in the paralleling module. It ensures that current measurements are consistent across all engines, allowing the module to balance the load effectively. This balance is essential for stable operation and prevents overloading of any single engine 14.

Power Factor Controller

The CT also feeds into the power factor controller by providing real-time current data. This allows the controller to make necessary adjustments to the power factor, enhancing the overall efficiency of the engine system. Accurate current information is key to maintaining a stable power factor, which in turn reduces energy waste and improves system reliability 15.

Conclusion

The Cummins 3011674 Current Transformer is a vital component in the electrical systems of commercial trucks and engines. Its accurate current measurement capabilities contribute to the efficient and safe operation of the vehicle’s electrical components. By integrating with various engine systems, this part ensures optimal performance, enhances safety, and improves overall reliability. Proper installation, maintenance, and adherence to safety practices are essential for maximizing the benefits of this Cummins part.


  1. Lejda, K., & Wos, P. (2012). Internal Combustion Engines. InTech.

  2. Lakshminarayanan, P. A., & Nayak, N. S. (2011). Critical Component Wear in Heavy Duty Engines. John Wiley & Sons.

  3. Bennett, S., & Norman, I. A. (2011). Heavy Duty Truck Systems, Fifth Edition. Delmar Cengage Learning.

  4. Cummins Inc. (n.d.). General Information. Bulletin Number 4915524, Owners Manual.

  5. Lejda, K., & Wos, P. (2012). Internal Combustion Engines. InTech.

  6. Bennett, S., & Norman, I. A. (2011). Heavy Duty Truck Systems, Fifth Edition. Delmar Cengage Learning.

  7. Lakshminarayanan, P. A., & Nayak, N. S. (2011). Critical Component Wear in Heavy Duty Engines. John Wiley & Sons.

  8. Cummins Inc. (n.d.). General Information. Bulletin Number 4915524, Owners Manual.

  9. Cummins Inc. (n.d.). General Information. Bulletin Number 4915524, Owners Manual.

  10. Lakshminarayanan, P. A., & Nayak, N. S. (2011). Critical Component Wear in Heavy Duty Engines. John Wiley & Sons.

  11. Bennett, S., & Norman, I. A. (2011). Heavy Duty Truck Systems, Fifth Edition. Delmar Cengage Learning.

  12. Lejda, K., & Wos, P. (2012). Internal Combustion Engines. InTech.

  13. Lakshminarayanan, P. A., & Nayak, N. S. (2011). Critical Component Wear in Heavy Duty Engines. John Wiley & Sons.

  14. Bennett, S., & Norman, I. A. (2011). Heavy Duty Truck Systems, Fifth Edition. Delmar Cengage Learning.

  15. Cummins Inc. (n.d.). General Information. Bulletin Number 4915524, Owners Manual.

SPECIFICATIONS

Hazardous Material
Non-Hazardous (NOI, ICE/Auto)
Package Dimensions
5.0 x 1.1 x 5.1 in
Weight
1.5 lb
* This information is provided as is and may be out of date. Please contact us or the manufacturer to verify warranty coverage.
* Variable geometry turbocharger and electronic actuator repairs are not eligible to be claimed as over-the-counter under New or ReCon parts warranty for parts installed after October 1, 2018.
* Diesel Oxidation Catalyst (DOC), Diesel Particulate Filter (DPF), Selective Catalyst Reduction (SCR) catalyst, and Electronic Control Module (ECM) repairs are not eligible to be claimed as over-the-counter under New or ReCon parts warranty for parts installed after January 1, 2020.
* These restrictions are only applicable to New parts and ReCon parts coverages for the components listed above sold to a customer in the US or Canada. All other coverages are excluded. All other regions are excluded.