5417138
Circuit Breaker
Cummins®
AVAILABLE
More than 10 are currently available
Ships within 2-4 business days
This truck part is made by Cummins®. We guarantee that all of our parts are from the OEM (original equipment manufacturer), ensuring a proper fit and quality manufacturing.
We honor the warranty provided by the original equipment manufacturer.
Introduction
The Cummins 5417138 Circuit Breaker is designed to safeguard the electrical systems of commercial trucks by protecting against overcurrent conditions, such as overloads or short circuits. This part automatically interrupts current flow when such conditions are detected, ensuring the integrity and reliability of the truck’s electrical system.
Basic Concepts of Circuit Breakers
A circuit breaker is an electrical protection device that interrupts current flow when it exceeds a predetermined threshold, preventing damage to electrical components and wiring 1. Unlike fuses, circuit breakers can be reset and reused, offering a more convenient and cost-effective solution for electrical protection.
Purpose of the 5417138 Circuit Breaker
This Cummins part is designed to protect the electrical system of commercial trucks from overcurrent conditions. It monitors current flow and automatically disconnects the circuit if the current exceeds safe levels, helping to prevent damage to electrical components and wiring.
Key Features
The 5417138 Circuit Breaker features high-quality materials for durability, a specific current rating for precise protection, and a manual reset mechanism for easy restoration of the circuit after an overcurrent event.
Benefits
Using this part in commercial trucks offers improved safety by protecting the electrical system from overcurrent conditions, enhanced durability for demanding operations, and reliable performance under various operating conditions.
Installation and Integration
Proper installation and integration of the 5417138 Circuit Breaker within a truck’s electrical system are vital for compatibility and optimal performance. Following the manufacturer’s guidelines for installation, including specific wiring instructions and mounting procedures, is important. Ensuring the circuit breaker is correctly sized for the circuit it protects is also critical for effective operation.
Troubleshooting and Maintenance
Regular maintenance and periodic inspections are important for ensuring the longevity and reliable operation of the 5417138 Circuit Breaker. Troubleshooting common issues may involve checking for proper installation, ensuring the circuit breaker is correctly rated for the circuit, and verifying that it operates correctly when tested. Maintenance tips include cleaning the circuit breaker and its contacts to prevent corrosion and ensuring that it is free from physical damage.
Common Failure Modes
Circuit breakers, including the 5417138, can experience common failure modes such as mechanical wear, electrical arcing, or contamination. Symptoms of failure may include the circuit breaker not tripping when it should or tripping unnecessarily. Causes of failure can range from physical damage to environmental factors such as moisture or dust. Corrective actions may involve replacing the circuit breaker or addressing the underlying cause of the failure. Regular maintenance is key to preventing failures and ensuring reliable operation.
Safety Considerations
When working with the 5417138 Circuit Breaker, it is important to follow safety practices to ensure safe operation and maintenance. This includes adhering to manufacturer guidelines and industry standards for electrical safety. Proper personal protective equipment should be worn when handling electrical components, and all work should be performed with the power disconnected to prevent electrical shock.
Cummins Overview
Cummins Inc. is a global power leader that designs, manufactures, and distributes engines, filtration, and power generation products. With a history spanning over a century, Cummins has established a reputation for quality, innovation, and customer satisfaction in the commercial truck industry. The company is committed to providing reliable and efficient power solutions that meet the needs of its customers worldwide.
Cummins Circuit Breaker 5417138 Compatibility
The 5417138 Circuit Breaker is designed to integrate seamlessly with several of Cummins’ engine models. This part is crucial for ensuring the electrical systems of these engines operate safely and efficiently. Below are the engine models that are compatible with the 5417138 Circuit Breaker:
QSK19 CM850 MCRS and QSK60 CM850 MCRS
Both the QSK19 CM850 MCRS and QSK60 CM850 MCRS engines feature a robust electrical system that benefits from the precise functionality provided by the 5417138 Circuit Breaker. This part is engineered to handle the specific electrical demands of these engines, ensuring reliable protection against overloads and short circuits.
QSK50 CM2150 K107
The QSK50 CM2150 K107 engine also incorporates the 5417138 Circuit Breaker into its electrical architecture. This integration is vital for maintaining the integrity of the engine’s electrical system, providing essential protection and control.
Each of these engines relies on the 5417138 Circuit Breaker to maintain optimal performance and safety. Cummins’ design ensures that this part fits perfectly within the electrical framework of these engines, providing a seamless and reliable solution for electrical protection.
Role of Part 5417138 Circuit Breaker in Engine Systems
The 5417138 Circuit Breaker is an essential component within the electrical architecture of engine systems, ensuring the integrity and reliability of power distribution. When integrated into the Junction Box Panel, this circuit breaker serves to safeguard the electrical circuits from overcurrent conditions that could arise from short circuits or excessive load demands.
In the context of the Junction Box Panel, the 5417138 Circuit Breaker acts as a protective device that automatically interrupts the electrical flow when current levels exceed safe thresholds. This proactive measure prevents potential damage to sensitive electronic components and wiring within the engine system. By doing so, it maintains the operational stability of the engine’s electrical network, allowing for consistent performance and longevity of the engine’s electronic systems.
Furthermore, the circuit breaker’s role extends to enhancing the safety of the engine system. It mitigates the risk of electrical fires that could be ignited by unchecked overcurrent situations. This safety feature is particularly important in high-stress environments where engine systems are subjected to varying loads and operating conditions.
Conclusion
The 5417138 Circuit Breaker plays a critical role in the electrical protection strategy of engine systems, working in concert with the Junction Box Panel to ensure both the efficiency and safety of the engine’s electrical components. Its integration into Cummins’ engine models underscores its importance in maintaining optimal performance and safety within commercial truck operations.
-
Stone, Richard. Introduction to Internal Combustion Engines, Fourth Edition. Macmillan, 2012.
↩
SPECIFICATIONS
RECOMMENDED PARTS
* Variable geometry turbocharger and electronic actuator repairs are not eligible to be claimed as over-the-counter under New or ReCon parts warranty for parts installed after October 1, 2018.
* Diesel Oxidation Catalyst (DOC), Diesel Particulate Filter (DPF), Selective Catalyst Reduction (SCR) catalyst, and Electronic Control Module (ECM) repairs are not eligible to be claimed as over-the-counter under New or ReCon parts warranty for parts installed after January 1, 2020.
* These restrictions are only applicable to New parts and ReCon parts coverages for the components listed above sold to a customer in the US or Canada. All other coverages are excluded. All other regions are excluded.